Yueqing Richuang Automation Equipment Co.,Ltd

Yueqing Richuang Automation Equipment Co.,Ltd

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Digital Clamp Meter Multimeter /

Fluke 1587FC Digital Clamp Meter Multimeter For Insulation Test 1587MTD

Contact Now
Yueqing Richuang Automation Equipment Co.,Ltd
Visit Website
Province/State:zhejiang
Country/Region:china
Contact Now

Fluke 1587FC Digital Clamp Meter Multimeter For Insulation Test 1587MTD

Ask Latest Price
Video Channel
Brand Name :Fluke
Model Number :Fluke1577 1587 1587FC 1587MTD
Certification :CE
Place of Origin :USA
MOQ :1 PCS
Price :consult for best discount
Payment Terms :T/T, , Western Union,Paypal,, MoneyGram,, L/C
Supply Ability :100 Pcs/month
Delivery Time :2-7 days
Packaging Details :Fluke original package
Usage :Universal Testing Machine
Power :Electronic
Display Type :Digital Only
Test voltage :50V To 1000V
Resistance :0.1 Ω to 2GΩ
Condition :New And Original
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Fluke 1587FC 1587MTD Digital Clamp Meter Multimeter Insulation Test FLUKE Insulation Multimeter

Product Description

Two powerful tools in one:

The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured,
true-rms digital multimeter in a single compact, handheld unit, which provides maximum versatility for both troubleshooting and
preventative maintenance. Like other tools that you have come to expect from Fluke, the 1587 and 1577 are rugged, reliable and easy to use. Whether you work on motors, generators, cables or switch-gear, the Fluke 1587/1577 Insulation Multimeters are ideally suited to help you with your tasks.

Overview

• Large display with backlight
• Insulation test (1587: 0.01 MW to 2 GW)
(1577: 0.1 MW to 600 MW)
• Insulation test voltages (1587: 50 V, 100 V, 250 V,
500 V, 1000 V),(1577: 500 V, 1000 V) for many
applications
• Live circuit detection prevents insulation test if voltage
> 30 V is detected for added user protection
• Auto-discharge of capacitive voltage for added user
protection
• AC/DC voltage, DC milliVolts, AC/DC milliamps,
Resistance (W), Continuity
• Filter for motor drive measurements (1587 only)

• Capacitance, diode test, temperature, Min/Max,
frequency (Hz) (1587 only)
• Auto power off to save battery power
• CAT III 1000 V, CAT IV 600 V measurement category
• Included accessories: Remote probe, test leads and probes, alligator clips, (K-type thermocouple,1587 only)
• Accepts optional Fluke TPAK™ magnetic hanging system to free your hands for other work
• Rugged, utility hard case allows you to bring everything you need for the job
• Three year warranty

Specifications Of Fluke 1587FC Insulation Multimeter

Electrical Specifications
AC voltage measurement
Range
600.0 mV Resolution 0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
6.000 V Resolution 0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
60.00 V Resolution 0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
600.0 V Resolution 0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
1000 V Resolution 1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
¹ 1 kHz bandwidth
Low-Pass Filter Voltage
Range
600.0 mV Resolution 0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
6.000 V Resolution 0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
60.00 V Resolution 0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
600.0 V Resolution 0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
1000 V Resolution 1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
DC Voltage Measurement
Range Resolution Accuracy ±(% of Rdg + Counts)
6.000 V dc 0.001 V ±(0.09% + 2)
60.00 V dc 0.01 V ±(0.09% + 2)
600.0 V dc 0.1 V ±(0.09% + 2)
1000 V dc 1 V ±(0.09% + 2)
Input impedance 10 MΩ (nominal), <100 pF
Normal mode rejection ratio >60 dB @ 50 Hz or 60 Hz
Common mode rejection ratio >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
Accuracies apply to ± 100% of range
DC Millivolts Measurement
Range Resolution Accuracy ±(% of Rdg + Counts)
600.0 mVdc 0.1 mV ±(0.1% + 1)
DC and AC Current Measurement
AC 45 Hz to 1000 Hz
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
Burden voltage (Typical) 2 mV/mA
Range 60 mA
Resolution 0.01 mA
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
Burden voltage (Typical) 2 mV/mA
DC
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden voltage (Typical) 2 mV/mA
Range 60 mA
Resolution 0.01 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden voltage (Typical) 2 mV/mA
Overload 600 mA for 2 minutes maximum
Fuse protection for mA input 0.44 mA, 1000 V, IR 10 kA
AC conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input